Home>mall>Electronics
0Líkaði

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

5.0
★★★★★
87
$10.99 /$13.41
  • *Name:

  • *Email:

  • *Phone:

  • *Quantity:

  • *Content:

  • Attachment:

    Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

$2.20 /$13.41

Örugg greiðsla tryggð

Ókeypis gjöf
Ókeypis gjöf með hverri kaupum
Sendingarstefna
Ókeypis venjuleg sending fyrir pantanir yfir $9.9
Skilastefna
Skilaðar vörur verða samþykktar innan 40 daga frá móttökudegi. Sérsniðnar vörur geta ekki verið skilaðar eða skipt. Vörur keyptar með raftökugjafakorti eru aðeins skiptanlegar; endurgreiðsla á ekki við.

Ókeypis gjöf

Velkomin á Roymall, faglegu vefsíðunni þinni fyrir gjafir úr vöruhúsi. Við metum og þökkum stuðning þinn og viljum sýna þakklæti með því að bæta við áhugaverðum þætti við kaupin þín. Þegar þú verslar hjá okkur færðu ekki aðeins aðgang að vörum í fyrsta flokki sem bæta lífsgæði þín heldur færðu einnig ókeypis gjöf með hverri pöntun. Tilbúin(n) að kanna safnið okkar og finna fullkomnu gjafirnar þínar? Skoðaðu úrval okkar af vörum úr vöruhúsi, pantaðu og bíððu eftir spennunni af ókeypis gjöfinni þinni sem fylgir kaupunum þínum.

Sendingarstefna

Við munum vinna hörðum höndum við að senda þér vörur eftir að hafa móttaka pöntun þína og tryggja að þær komist heil og hrauskar til þín. Sendingarupplýsingar verða í staðfestingarpóstinum þínum.Í flestum tilfellum eru pantanir afgreiddar innan 2 daga. Undir sérstökum kringumstæðum getur það tekið lengri tíma eins og hér segir: Þegar þú pantar á laugardegi, sunnudegi eða á frídögum, gæti það tekið 2 daga lengri tíma.Venjulega þarf 5-7 virka daga (mánudaga til föstudaga) án þess að flugseinkun eða önnur umhverfisþættir hafi áhrif.Þar sem sendingarþjónusta okkar er alþjóðleg mun sendingartíminn ráðast af staðsetningu þinni, svo það gæti tekið nokkurn tíma og vinsamlegast bíðið þolinmóð ef þú ert í afskekktum svæðum eða löndum.

1. Skilastefna

Við tökum aðeins við vörum sem keyptar eru á roymall.com. Ef þú kaupir af staðbundnum dreifingaraðilum okkar eða öðrum söluaðilum geturðu ekki skilað þeim til okkar. Lokasöluvörur eða ókeypis gjafir eru ekki samþykktar til skila.Til að eiga rétt á skilum verður vara þín að vera ónotuð og í sömu ástandi og þú fékkst hana. Hún verður einnig að vera í upprunalegum umbúðum.Eftir að hafa fengið skilaleiðbeiningar frá okkur, vinsamlegast pakkaðu vörunum sem skila á og skilaðu pakkanum á staðbundnu pósthúsi eða öðrum sendingaraðila.
Við munum afgreiða skilaða eða skipta vöru innan 3-5 virkra daga eftir að hún berst til okkar. Endurgreiðsla verður afgreidd og endurgreidd sjálfkrafa á upprunalega greiðslumáta þinn.Engar skil eða skipti eru möguleg ef vara var framleidd sérstaklega, þar á meðal sérstaklega stærð, lit eða prentun.Ef þú þarft meiri hjálp, vinsamlegast hafðu samband við okkur. service@roymall.com eða Whatsapp: +8619359849471

2. Endurgreiðslustefna

Þú færð fulla endurgreiðslu eða 100% afslátt í búðina eftir að við höfum móttekið og skoðað skilaða pakkann. Endurgreiðsla verður afgreidd og endurgreidd sjálfkrafa á upprunalega greiðslumáta þinn.Athugaðu að sendingarkostnaður og allar tollgjöld eða gjöld eru ekki endurgreidd. Viðbótar sendingarkostnaður er ekki endurgreiddur þegar pakki hefur verið sendur. Þú berð ábyrgð á að greiða þessi gjöld og við getum ekki veitt undanþágu eða endurgreitt þau, jafnvel þótt pöntunin sé skilað til okkar.Þegar við höfum móttekið og staðfest skilaða vöru þína, sendum við þér tölvupóst til að tilkynna að við höfum móttekið skilaða vöru þína. Við munum einnig tilkynna þér um samþykki eða höfnun á endurgreiðslu þinni.Ef þú átt í vandræðum með endurgreiðsluferlið, vinsamlegast hafðu samband við okkur. service@roymall.com eða Whatsapp: +8619359849471

Specifications:


1: Power supply voltage: DC6--40V, voltage detection range DC 0--60V, suitable for less than 60V of the various batteries, voltage measurement error u00b1 0.1V.

2: charge and discharge time (OP) range: 0 - 999 minutes.



Features:


1. Battery charge and discharge intelligent control

2. You can set the charge and discharge time

3. With serial communication function, real-time monitoring of the working status of the relay through the serial port

4. Additional signal output, when the relay to meet the conditions, the output high, you can control other equipment

5. A key emergency stop function (STOP button), with reverse protection, reverse does not burn



Operating mode:


Voltage upper limit: UL1, voltage lower limit nL1, the voltage upper limit is greater than the voltage lower limit (UL1> nL1)

U-1: Charging measurement: When the measured voltage is lower than the lower limit voltage, the relay pulls above; the upper limit voltage, the relay is disconnected.

U-2: Charge measurement time control: set the charging time (OP); when the measured voltage is lower than the lower limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage is higher than the upper limit voltage , The relay is disconnected.

U-3: Discharge detection: When the measured voltage is lower than the lower limit voltage, the relay is off, above the upper limit voltage, the relay pulls.

U-4: Discharge detection time control: set the discharge time (OP); when the measured voltage is higher than the upper limit voltage, the relay pull, and then start the countdown OP time, the end of the timer, the relay off; when the measured voltage below the lower limit voltage , The relay is disconnected.

U-5: Voltage in the range, the relay pull: when the measured voltage between the upper and lower limits, the relay pull, the other circumstances open.

U-6: Voltage outside the interval, the relay pull: the measured voltage below the lower limit voltage or higher than the upper limit voltage, the relay pull, the other case the relay is off.



How to set parameters:


1. First, according to their needs, to determine the requirements of the work model;

2. According to the working mode of the relay, in the main interface (when the module is powered on, it will flash the current mode of operation, the default U-1 mode, and then enter the main interface) press the SET button for 2 seconds and then release, enter the selection Mode interface, UP, DOWN button to select the mode to be set (U-1 ~ U-6);

3. After selecting the mode, assume that we have selected the U-1 mode and press the SET button to set the corresponding parameter. The parameter to be set will flash (UL1 voltage upper limit, nL1 voltage lower limit, OP conduction time), press UP, DOWN Key to increase or decrease, you can always press the key to quickly increase or decrease, press the SET button to set the current mode of the next parameter, the process above;

4. Set the parameters, and then press the SET button for 2 seconds to release, the current setting mode will flash, and then return to the main interface, set the parameters of success!

5. In the main interface, press the DOWN key to achieve voltage and time switching.



Mode selection interface:


Press the SET button for a long time to enter the mode selection interface, set the finished, a long time press the SET button and then release the exit mode selection interface, back to the main interface.



Additional features:


1. Data upload: through the serial port to achieve data upload, interval 1s upload a voltage and run time, easy to post-data analysis;

2. Serial port settings parameters: You can set the mode and parameters through the serial port, more convenient;

3. An extra signal output, when the relay to meet the conditions, the output high, the other output low.

Serial port control (TTL level communication)

Communication standard:

The baud rate is 115200 bps

Data bits: 8

Stop bit: 1

Check digit: none

Flow control: none

Serial command:

"U-1": Operating mode (range U-1 to U-6)

"000": 0 - does not enable timing function, non-0 - enable timing function (range 001 to 999)

"Dw02.9": Set the lower limit voltage

"Up10.1": set the upper limit voltage (range 00.0V ~ 99.9V)

"Get": Get the current settings

"On": Allows the relay to turn on

"Off": Always turn off the relay

"Start": start uploading data

"Stop": stop uploading data

The above command can be any combination of two, need to be separated by commas

Such as: "dw02.9, up10.1" set the lower limit voltage 02.9V upper limit voltage 10.1V

Upload Status: Test Voltage + On Time + Status

"00.0V, 00: 00: 00, OP r n"

00.0V: Measured voltage

00:00:00: Relay on time

Status: OP relay on, CL relay off



STOP key function expansion:


Relay enable mode:

1. ON: OP conduction time, the relay allows conduction;

2. OFF: The relay is disabled and is always off;

Press the STOP button on the main interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is an emergency stop function, a key to disconnect the relay)

Sleep mode:

1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation;

2. O-d normal mode: digital tube is always open display;

Press and hold the STOP button for 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.



Package include:


1u00d7Battery Charger Discharger Board

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

DC 6-40V Battery Charger Discharger Board Integrated Voltmeter Undervoltage Overvoltage Protection Module Timing Charging Discharging Communication Function

Karfa mín Karfa (29)
Eftirlæti mín Eftirlæti (0)